Product Feature:
- Small diameter: 3~25 mm
- No limit on length: 20~2000 mm
- High power density: 20 W / cm2
Technical Parameters and QC Testing:
- Heating up time: ¡Ü 15 min
- Power Tolerance:
¡À 10% (if rated power ¡Ü 100 W)
-10% ~ +5 % or 10 W (if rated power > 100 W)
- Leakage Current:
Cold leakage current ¡Ü 0.5 mA
Hot leakage current: I ¡Ü 5 mA
I = 1/6£¨tT¡Á0.00001£©
I¡ª hot leakage current (mA)
t¡ª heating length (mm)
T¡ª working temperature (¡æ)
If there are several heaters in series, the hot leakage should be tested upon the full series circuit.
- Insulation Resistance:
Cold insulation resistance ¡Ý50 M¦¸
Hot insulation resistance R ¡Ý1 M¦¸
R=¡¸£¨10-0.015T£©/t¡¹¡Á0.001
R¡ª hot insulation resistance (M¦¸)
t¡ª heating length (mm)
T¡ª working temperature (¡æ)
Other testing:
- Withstand Voltage Strength
- Power on-off
- Thermal resistant
- Overload capacity
|